top of page

HVAC

Heating, Ventilation, and Air Conditioning and refers to the systems used to control the temperature, humidity, and air quality in indoor spaces like homes and buildings.

​

Precise HVAC systems are essential for maintaining a comfortable indoor climate. Pressure and current sensors from Luksens provide the accuracy and reliability needed to meet the most demanding requirements.

Air Conditioner

Typical applications

  • VAV comerical air conditioning

  • Refrigeration systems

  • Ventilation motor drives

  • Heat pumps

  • Pellet and gas heating systems

  • Gas boiler

Precision Current Sensing for HVAC Compressors: Luksens C03/C06/K03

​

In variable frequency air conditioning systems, efficient compressor control relies on precise current feedback. Luksens’ C03, C06, and K03 series current sensors are specifically for the HVAC industry, offering a complete monitoring solution. We have established a comprehensive product matrix covering a wide current range from 30A to 300A.

Whether monitoring low-current startups for ultra-quiet operation or tracking high currents during full-load cycles, Luksens sensors provide high linearity and low temperature drift. Our technology empowers your systems to achieve higher Seasonal Energy Efficiency Ratios (SEER) and stable, long-term operation.

C03-30A

C03-50A

open loop hvac current sensor
open loop hvac current sensor
open loop current sensor
open loop current sensor

C06-100A

K03D200S05

​Optimizing VAV Efficiency with Advanced PA Pressure Sensors​

​

Optimize your VAV equipment with PA pressure sensors designed for longevity and resilience. Our sensors tackle the toughest HVAC challenges, combining hermetic sealing with superior environmental protection:​

  • Humidity Resistant: Built to operate reliably for long periods in extremely humid and condensing conditions.

  • Ultra-Low Leakage: Features a leakage rate of <1g/year for maximum system tightness.

  • Versatile Integration: Compatible with a wide range of refrigerants and available with flexible connections (threads or copper tubes) for easy installation.

Choose a sensor that ensures stability and prevents moisture-induced failures in your critical air management systems.

​

​

PA hvac pressure sensor
pressuresensor.png

Related Products

2.5±0.027V/A

5V

30A

1.50%

—

PCB mount

C03-30A Open-Loop Current Sensor

2.5 ± 0.025V/A

5V

50A

1%

—

PCB mount

C03-50A Open-Loop current sensor

2.5±2V

5V

50A|100A|150A|200A|250A|300A|400A

1%

—

PCB mount

C06 series Open-Loop current sensor

2.5±2V

5V

10A|20A|30A|40A|50A

1%

​

SOIC8 mount

C08K Series | 400 kHz (SiC-Ready) ICS

1.65±1.32V

3.3V

10A|20A|30A|40A|50A

1%

​

SOIC8 mount

C08K-xxA33 Series | 400 kHz (SiC-Ready) ICS

2.5±2V

5V

10A|20A|30A|40A|50A

1%

​

SOIC8 mount

C08M Series | 2 MHz (GaN-optimized) ICS

1.65±1.32V

3.3V

10A|20A|30A|40A|50A

1%

​

SOIC8 mount

C08M-xxA33 Series | 2 MHz (GaN-optimized) ICS

2.5±2V

5V

50A|90A|100A|125A|150A|200A|250A

1%

​

SOW10 mount

C10K Series | 400 kHz (SiC-Ready) ICS

2.5±2V

5V

50A|90A|100A|125A|150A|200A|250A

1%

​

SOW10 mount

C10M Series | 2 MHz (GaN-optimized) ICS

2.5±2V

5V

10A|20A|30A|50A|65A|100A

1%

​

SOW16 mount

C16K Series | 400 kHz (SiC-Ready) ICS

2.5±2V

5V

10A|20A|30A|50A|65A|100A

1%

​

SOW16 mount

C16M Series | 2 MHz (GaN-optimized) ICS

2.5 ± 0.8V

5V

50A|100A|200A|300A|400A|500A|600A

1%

A2501WV-4P, A2543WV-4P

Stud mount

K03xxxxS05 series Open-Loop current sensor

2.5±1.5V

5V

60A

1%

​

PCB mount

K18D060S05 Open-Loop current sensor

0-10VDC, 14 to 30VDC|0.5-4.5VDC ratio, 5V|1-5VDC, 12 to 30VDC|4-20mA, 12 to 30VDC

—

0...100bar

0.5% FS

RK03FB, Metri-Pack 150, DIN 175301-803-A PG9, Direct cable

Threaded mount

P02 series piezoresistive pressure transmitter

0-10VDC, 14 to 30VDC|0.5-4.5VDC ratio, 5V|0.5-2.5VDC, 5VDC|0.5-3.5VDC, 5VDC|1-5VDC, 12 to 30VDC|4-20mA, 12 to 30VDC

—

0...60bar

0.5% FS

RK03FB, Metri-Pack 150, DIN 175301-803C PG7, M12x1, Bayonet, Direct cable

Threaded mount

PA series OEM pressure transmitter

Name

Supply voltage

Measuring

range

Sensor

output

Accuracy

Electrical

connector

Mounting

PDF