top of page
PSC series piezoresistive ceramic pressure sensor

PSC series piezoresistive ceramic pressure sensor

The PSC series pressure sensors feature a ceramic cell using the piezoresistive principle. A Wheatstone bridge is screen-printed on one side of the ceramic diaphragm via thick film technology, while the other side directly contacts the measured medium. The Al₂O₃ ceramic offers excellent chemical resistance, eliminating the need for additional protection. The monolithic design with a reinforced outer area allows O-ring mounting in housings. PSC sensors ensure reliability under temperature changes, provide precise linearity and minimal hysteresis.

 

Parameter & Feature:

 

  • Pressure Range: 0 ... 60 bar  
  • Technology: Ceramic piezoresistive principle (Wheatstone bridge screen-printed on a ceramic diaphragm using thick-film technology, with direct contact to the measured medium)
  • Mount: Flange mount
  • connections: Pre-tinned pads, Wires 50.8 mm
  • Power supply: 2…10 V
  • Output: 2.0-4.0 mV / V, 2-10 VDC
  • Accuracy: 0.2% FS 
  • Response time: <1 ms
  • Operating temperature range: -40 °C…105 °C
  • Range can be customized
  • l2O3 ceramic ingress protection rating for chemical resistance (aggressive gases, most of solvents and acids, etc.)

 

 

Suitable for the following:

  • Process control
  • Environmental control
  • Meters and instruments
  • Medical instrument
bottom of page